Get-LMLogSource
Syntax
Section titled “Syntax”All (Default)
Section titled “All (Default)”Get-LMLogSource [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]Get-LMLogSource [-Id <Int32>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]Get-LMLogSource [-Name <String>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]Filter
Section titled “Filter”Get-LMLogSource [-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]Description
Section titled “Description”The Get-LMLogSource function retrieves log source configurations from LogicMonitor. It can retrieve all log sources, a specific source by ID or name, or filter the results.
Examples
Section titled “Examples”Example 1
Section titled “Example 1”#Retrieve all log sourcesGet-LMLogSourceExample 2
Section titled “Example 2”#Retrieve a specific log source by nameGet-LMLogSource -Name "Linux-Syslog"Parameters
Section titled “Parameters”The ID of the specific log source to retrieve.
Type: Int32Parameter Sets: IdAliases:
Required: FalsePosition: NamedDefault value: 0Accept pipeline input: FalseAccept wildcard characters: FalseThe name of the specific log source to retrieve.
Type: StringParameter Sets: NameAliases:
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False-Filter
Section titled “-Filter”A filter object to apply when retrieving log sources.
Type: ObjectParameter Sets: FilterAliases:
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False-BatchSize
Section titled “-BatchSize”The number of results to return per request. Must be between 1 and 1000. Defaults to 1000.
Type: Int32Parameter Sets: (All)Aliases:
Required: FalsePosition: NamedDefault value: 1000Accept pipeline input: FalseAccept wildcard characters: False-ProgressAction
Section titled “-ProgressAction”Fill ProgressAction Description
Type: ActionPreferenceParameter Sets: (All)Aliases: proga
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: FalseCommonParameters
Section titled “CommonParameters”This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
Inputs
Section titled “Inputs”None. You cannot pipe objects to this command.
Section titled “None. You cannot pipe objects to this command.”Outputs
Section titled “Outputs”Returns LogicMonitor.Logsource objects.
Section titled “Returns LogicMonitor.Logsource objects.”You must run Connect-LMAccount before running this command.