Get-LMDeviceDatasourceInstanceAlertSetting
Syntax
Section titled “Syntax”Name-dsName
Section titled “Name-dsName”Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceName <string> -Name <string> -InstanceName <string> [-Filter <Object>] [-BatchSize <int>] [<CommonParameters>]Id-dsName
Section titled “Id-dsName”Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceName <string> -Id <int> -InstanceName <string> [-Filter <Object>] [-BatchSize <int>] [<CommonParameters>]Name-dsId
Section titled “Name-dsId”Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceId <int> -Name <string> -InstanceName <string> [-Filter <Object>] [-BatchSize <int>] [<CommonParameters>]Id-dsId
Section titled “Id-dsId”Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceId <int> -Id <int> -InstanceName <string> [-Filter <Object>] [-BatchSize <int>] [<CommonParameters>]Description
Section titled “Description”The Get-LMDeviceDatasourceInstanceAlertSetting function retrieves the alert configuration settings for a specific device datasource instance. It supports identifying the device and datasource by either ID or name, and allows filtering of the results.
Examples
Section titled “Examples”EXAMPLE 1
Section titled “EXAMPLE 1”#Retrieve alert settings using namesGet-LMDeviceDatasourceInstanceAlertSetting -Name "MyDevice" -DatasourceName "MyDatasource" -InstanceName "MyInstance"EXAMPLE 2
Section titled “EXAMPLE 2”#Retrieve alert settings using IDs with filterGet-LMDeviceDatasourceInstanceAlertSetting -Id 123 -DatasourceId 456 -InstanceName "MyInstance" -Filter $filterObjectParameters
Section titled “Parameters”-BatchSize
Section titled “-BatchSize”The number of results to return per request. Must be between 1 and 1000. Defaults to 1000.
Type: System.Int32DefaultValue: 1000SupportsWildcards: falseAliases: []ParameterSets:- Name: (All) Position: Named IsRequired: false ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: falseDontShow: falseAcceptedValues: []HelpMessage: ''-DatasourceId
Section titled “-DatasourceId”The ID of the datasource. Required for Id-dsId and Name-dsId parameter sets.
Type: System.Int32DefaultValue: 0SupportsWildcards: falseAliases: []ParameterSets:- Name: Name-dsId Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: false- Name: Id-dsId Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: falseDontShow: falseAcceptedValues: []HelpMessage: ''-DatasourceName
Section titled “-DatasourceName”The name of the datasource. Required for Id-dsName and Name-dsName parameter sets.
Type: System.StringDefaultValue: ''SupportsWildcards: falseAliases: []ParameterSets:- Name: Name-dsName Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: false- Name: Id-dsName Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: falseDontShow: falseAcceptedValues: []HelpMessage: ''-Filter
Section titled “-Filter”A filter object to apply when retrieving alert settings. This parameter is optional.
Type: System.ObjectDefaultValue: ''SupportsWildcards: falseAliases: []ParameterSets:- Name: (All) Position: Named IsRequired: false ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: falseDontShow: falseAcceptedValues: []HelpMessage: ''The ID of the device. Can be specified using the DeviceId alias. Required for Id-dsId and Id-dsName parameter sets.
Type: System.Int32DefaultValue: 0SupportsWildcards: falseAliases:- DeviceIdParameterSets:- Name: Id-dsName Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: false- Name: Id-dsId Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: falseDontShow: falseAcceptedValues: []HelpMessage: ''-InstanceName
Section titled “-InstanceName”The name of the instance to retrieve alert settings for. This parameter is mandatory.
Type: System.StringDefaultValue: ''SupportsWildcards: falseAliases: []ParameterSets:- Name: (All) Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: falseDontShow: falseAcceptedValues: []HelpMessage: ''The name of the device. Can be specified using the DeviceName alias. Required for Name-dsName and Name-dsId parameter sets.
Type: System.StringDefaultValue: ''SupportsWildcards: falseAliases:- DeviceNameParameterSets:- Name: Name-dsId Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: false- Name: Name-dsName Position: Named IsRequired: true ValueFromPipeline: false ValueFromPipelineByPropertyName: false ValueFromRemainingArguments: falseDontShow: falseAcceptedValues: []HelpMessage: ''CommonParameters
Section titled “CommonParameters”This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutBuffer, -OutVariable, -PipelineVariable, -ProgressAction, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.