Skip to content

Get-LMDatasourceAssociatedDevice

Terminal window
Get-LMDatasourceAssociatedDevice -Id <Int32> [-Filter <Object>] [-BatchSize <Int32>]
[-ProgressAction <ActionPreference>] [<CommonParameters>]
Terminal window
Get-LMDatasourceAssociatedDevice [-Name <String>] [-Filter <Object>] [-BatchSize <Int32>]
[-ProgressAction <ActionPreference>] [<CommonParameters>]
Terminal window
Get-LMDatasourceAssociatedDevice [-DisplayName <String>] [-Filter <Object>] [-BatchSize <Int32>]
[-ProgressAction <ActionPreference>] [<CommonParameters>]

The Get-LMDatasourceAssociatedDevice function retrieves all devices that are associated with a specific datasource. It can identify the datasource by ID, name, or display name.

Terminal window
#Retrieve devices associated with a datasource by ID
Get-LMDatasourceAssociatedDevice -Id 123
Terminal window
#Retrieve devices associated with a datasource by name
Get-LMDatasourceAssociatedDevice -Name "CPU"

The ID of the datasource to retrieve associated devices for. This parameter is mandatory when using the Id parameter set.

Type: Int32
Parameter Sets: Id
Aliases:
Required: True
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

The name of the datasource to retrieve associated devices for. Part of a mutually exclusive parameter set.

Type: String
Parameter Sets: Name
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

The display name of the datasource to retrieve associated devices for. Part of a mutually exclusive parameter set.

Type: String
Parameter Sets: DisplayName
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

A filter object to apply when retrieving associated devices. This parameter is optional.

Type: Object
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

The number of results to return per request. Must be between 1 and 1000. Defaults to 1000.

Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: 1000
Accept pipeline input: False
Accept wildcard characters: False

Fill ProgressAction Description

Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

None. You cannot pipe objects to this command.

Section titled “None. You cannot pipe objects to this command.”

Returns LogicMonitor.DatasourceDevice objects.

Section titled “Returns LogicMonitor.DatasourceDevice objects.”

You must run Connect-LMAccount before running this command.