Set-LMDeviceProperty

Terminal window
Set-LMDeviceProperty -Id <Int32> -PropertyName <String> -PropertyValue <String>
[-ProgressAction <ActionPreference>] [-WhatIf] [-Confirm] [<CommonParameters>]
Terminal window
Set-LMDeviceProperty -Name <String> -PropertyName <String> -PropertyValue <String>
[-ProgressAction <ActionPreference>] [-WhatIf] [-Confirm] [<CommonParameters>]

The Set-LMDeviceProperty function modifies the value of a specific property for a device in LogicMonitor.

Terminal window
Set-LMDeviceProperty -Id 123 -PropertyName "Location" -PropertyValue "New York"
Updates the "Location" property to "New York" for the device with ID 123.

Specifies the ID of the device. This parameter is mandatory when using the ‘Id’ parameter set.

Type: Int32
Parameter Sets: Id
Aliases:
Required: True
Position: Named
Default value: 0
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False

Specifies the name of the device. This parameter is mandatory when using the ‘Name’ parameter set.

Type: String
Parameter Sets: Name
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

Specifies the name of the property to update.

Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

Specifies the new value for the property.

Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

Fill ProgressAction Description

Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

You can pipe objects containing Id properties to this function.

Section titled “You can pipe objects containing Id properties to this function.”

Returns the response from the API indicating the success of the property update.

Section titled “Returns the response from the API indicating the success of the property update.”

This function requires a valid LogicMonitor API authentication.