Get-LMDeviceInstanceList
Syntax
Section titled “Syntax”Id (Default)
Section titled “Id (Default)”Get-LMDeviceInstanceList -Id <Int32> [-Filter <Object>] [-BatchSize <Int32>] [-CountOnly <Boolean>] [-ProgressAction <ActionPreference>] [<CommonParameters>]Get-LMDeviceInstanceList [-Name <String>] [-Filter <Object>] [-BatchSize <Int32>] [-CountOnly <Boolean>] [-ProgressAction <ActionPreference>] [<CommonParameters>]Description
Section titled “Description”The Get-LMDeviceInstanceList function retrieves all instances associated with a specific device in LogicMonitor. The device can be identified by either ID or name, and the results can be filtered.
Examples
Section titled “Examples”Example 1
Section titled “Example 1”#Retrieve instances by device IDGet-LMDeviceInstanceList -Id 123Example 2
Section titled “Example 2”#Get instance count for a deviceGet-LMDeviceInstanceList -Name "Production-Server" -CountOnly $trueParameters
Section titled “Parameters”The ID of the device to retrieve instances from. Required for Id parameter set.
Type: Int32Parameter Sets: IdAliases:
Required: TruePosition: NamedDefault value: 0Accept pipeline input: FalseAccept wildcard characters: FalseThe name of the device to retrieve instances from. Required for Name parameter set.
Type: StringParameter Sets: NameAliases:
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False-Filter
Section titled “-Filter”A filter object to apply when retrieving instances. This parameter is optional.
Type: ObjectParameter Sets: (All)Aliases:
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False-BatchSize
Section titled “-BatchSize”The number of results to return per request. Must be between 1 and 1000. Defaults to 1000.
Type: Int32Parameter Sets: (All)Aliases:
Required: FalsePosition: NamedDefault value: 1000Accept pipeline input: FalseAccept wildcard characters: False-CountOnly
Section titled “-CountOnly”When set to true, returns only the total count of instances instead of the instance details.
Type: BooleanParameter Sets: (All)Aliases:
Required: FalsePosition: NamedDefault value: FalseAccept pipeline input: FalseAccept wildcard characters: False-ProgressAction
Section titled “-ProgressAction”Fill ProgressAction Description
Type: ActionPreferenceParameter Sets: (All)Aliases: proga
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: FalseCommonParameters
Section titled “CommonParameters”This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
Inputs
Section titled “Inputs”None. You cannot pipe objects to this command.
Section titled “None. You cannot pipe objects to this command.”Outputs
Section titled “Outputs”Returns device instance objects or a count if CountOnly is specified.
Section titled “Returns device instance objects or a count if CountOnly is specified.”You must run Connect-LMAccount before running this command.