Get-LMDeviceDatasourceInstanceAlertSetting
Syntax
Name-dsName
Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceName <String> -Name <String> -InstanceName <String> [-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Id-dsName
Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceName <String> -Id <Int32> -InstanceName <String> [-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Name-dsId
Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceId <Int32> -Name <String> -InstanceName <String> [-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Id-dsId
Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceId <Int32> -Id <Int32> -InstanceName <String> [-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Description
The Get-LMDeviceDatasourceInstanceAlertSetting function retrieves the alert configuration settings for a specific device datasource instance. It supports identifying the device and datasource by either ID or name, and allows filtering of the results.
Examples
Example 1
#Retrieve alert settings using namesGet-LMDeviceDatasourceInstanceAlertSetting -Name "MyDevice" -DatasourceName "MyDatasource" -InstanceName "MyInstance"
Example 2
#Retrieve alert settings using IDs with filterGet-LMDeviceDatasourceInstanceAlertSetting -Id 123 -DatasourceId 456 -InstanceName "MyInstance" -Filter $filterObject
Parameters
-DatasourceName
The name of the datasource. Required for Id-dsName and Name-dsName parameter sets.
Type: StringParameter Sets: Name-dsName, Id-dsNameAliases:
Required: TruePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False
-DatasourceId
The ID of the datasource. Required for Id-dsId and Name-dsId parameter sets.
Type: Int32Parameter Sets: Name-dsId, Id-dsIdAliases:
Required: TruePosition: NamedDefault value: 0Accept pipeline input: FalseAccept wildcard characters: False
-Id
The ID of the device. Can be specified using the DeviceId alias. Required for Id-dsId and Id-dsName parameter sets.
Type: Int32Parameter Sets: Id-dsName, Id-dsIdAliases: DeviceId
Required: TruePosition: NamedDefault value: 0Accept pipeline input: FalseAccept wildcard characters: False
-Name
The name of the device. Can be specified using the DeviceName alias. Required for Name-dsName and Name-dsId parameter sets.
Type: StringParameter Sets: Name-dsName, Name-dsIdAliases: DeviceName
Required: TruePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False
-InstanceName
The name of the instance to retrieve alert settings for. This parameter is mandatory.
Type: StringParameter Sets: (All)Aliases:
Required: TruePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False
-Filter
A filter object to apply when retrieving alert settings. This parameter is optional.
Type: ObjectParameter Sets: (All)Aliases:
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False
-BatchSize
The number of results to return per request. Must be between 1 and 1000. Defaults to 1000.
Type: Int32Parameter Sets: (All)Aliases:
Required: FalsePosition: NamedDefault value: 1000Accept pipeline input: FalseAccept wildcard characters: False
-ProgressAction
Fill ProgressAction Description
Type: ActionPreferenceParameter Sets: (All)Aliases: proga
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
Inputs
None. You cannot pipe objects to this command.
Outputs
Returns LogicMonitor.AlertSetting objects.
Notes
You must run Connect-LMAccount before running this command.