Get-LMConfigSource
Syntax
All (Default)
Get-LMConfigSource [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Id
Get-LMConfigSource [-Id <Int32>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Name
Get-LMConfigSource [-Name <String>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Filter
Get-LMConfigSource [-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Description
The Get-LMConfigSource function retrieves configuration sources from LogicMonitor based on specified parameters. It can return a single configuration source by ID or name, or multiple sources using filters.
Examples
Example 1
#Retrieve a configuration source by IDGet-LMConfigSource -Id 123
Example 2
#Retrieve a configuration source by nameGet-LMConfigSource -Name "Cisco Config"
Parameters
-Id
The ID of the configuration source to retrieve. This parameter is part of a mutually exclusive parameter set.
Type: Int32Parameter Sets: IdAliases:
Required: FalsePosition: NamedDefault value: 0Accept pipeline input: FalseAccept wildcard characters: False
-Name
The name of the configuration source to retrieve. This parameter is part of a mutually exclusive parameter set.
Type: StringParameter Sets: NameAliases:
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False
-Filter
A filter object to apply when retrieving configuration sources. This parameter is part of a mutually exclusive parameter set.
Type: ObjectParameter Sets: FilterAliases:
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False
-BatchSize
The number of results to return per request. Must be between 1 and 1000. Defaults to 1000.
Type: Int32Parameter Sets: (All)Aliases:
Required: FalsePosition: NamedDefault value: 1000Accept pipeline input: FalseAccept wildcard characters: False
-ProgressAction
Fill ProgressAction Description
Type: ActionPreferenceParameter Sets: (All)Aliases: proga
Required: FalsePosition: NamedDefault value: NoneAccept pipeline input: FalseAccept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
Inputs
None. You cannot pipe objects to this command.
Outputs
Returns LogicMonitor.Datasource objects.
Notes
You must run Connect-LMAccount before running this command.